Part Number Hot Search : 
DG2031 C4696 11N120 C2501 ABMM1 C34910 BC178 BU4328G
Product Description
Full Text Search
 

To Download HGTG30N60C3 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 HGTG30N60C3
Data Sheet January 2000 File Number 4042.2
63A, 600V, UFS Series N-Channel IGBT
The HGTG30N60C3 is a MOS gated high voltage switching device combining the best features of MOSFETs and bipolar transistors. The device has the high input impedance of a MOSFET and the low on-state conduction loss of a bipolar transistor. The much lower on-state voltage drop varies only moderately between 25oC and 150oC. The IGBT is ideal for many high voltage switching applications operating at moderate frequencies where low conduction losses are essential, such as: AC and DC motor controls, power supplies and drivers for solenoids, relays and contactors. Formerly Developmental Type TA49051.
Features
* 63A, 600V at TC = 25oC * 600V Switching SOA Capability * Typical Fall Time. . . . . . . . . . . . . . . . 230ns at TJ = 150oC * Short Circuit Rating * Low Conduction Loss
Packaging
JEDEC STYLE TO-247
E C G
Ordering Information
PART NUMBER HGTG30N60C3 PACKAGE TO-247 BRAND G30N60C3
NOTE: When ordering, use the entire part number.
Symbol
C
G
E
INTERSIL CORPORATION IGBT PRODUCT IS COVERED BY ONE OR MORE OF THE FOLLOWING U.S. PATENTS 4,364,073 4,598,461 4,682,195 4,803,533 4,888,627 4,417,385 4,605,948 4,684,413 4,809,045 4,890,143 4,430,792 4,620,211 4,694,313 4,809,047 4,901,127 4,443,931 4,631,564 4,717,679 4,810,665 4,904,609 4,466,176 4,639,754 4,743,952 4,823,176 4,933,740 4,516,143 4,639,762 4,783,690 4,837,606 4,963,951 4,532,534 4,641,162 4,794,432 4,860,080 4,969,027 4,587,713 4,644,637 4,801,986 4,883,767
1
CAUTION: These devices are sensitive to electrostatic discharge; follow proper ESD Handling Procedures. 1-888-INTERSIL or 321-724-7143 | Copyright (c) Intersil Corporation 2000
HGTG30N60C3
Absolute Maximum Ratings
TC = 25oC, Unless Otherwise Specified HGTG30N60C3 Collector To Emitter Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .BVCES Collector Current Continuous At TC = 25oC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IC25 At TC = 110oC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IC110 Collector Current Pulsed (Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ICM Gate To Emitter Voltage Continuous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VGES Gate To Emitter Voltage Pulsed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VGEM Switching Safe Operating Area at TJ = 150oC (Figure 14) . . . . . . . . . . . . . . . . . . . . . . SSOA Power Dissipation Total at TC = 25oC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PD Power Dissipation Derating TC > 25oC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reverse Voltage Avalanche Energy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EARV Operating and Storage Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . TJ, TSTG Maximum Lead Temperature for Soldering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TL Short Circuit Withstand Time (Note 2) at VGE = 15V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .tSC Short Circuit Withstand Time (Note 2) at VGE = 10V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .tSC 600 63 30 252 20 30 60A at 600V 208 1.67 100 -40 to 150 260 4 15 UNITS V A A A V V W W/oC mJ oC oC s s
CAUTION: Stresses above those listed in "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
NOTES: 1. Repetitive Rating: Pulse width limited by maximum junction temperature. 2. VCE(PK) = 360V, TJ = 125oC, RG = 25.
Electrical Specifications
PARAMETER
TC = 25oC, Unless Otherwise Specified SYMBOL BVCES BVECS ICES VCE(SAT) VGE(TH) IGES SSOA TEST CONDITIONS IC = 250A, VGE = 0V IC = 10mA, VGE = 0V VCE = BVCES VCE = BVCES IC = IC110, VGE = 15V IC = 250A, VCE = VGE VGE = 20V TJ = 150oC, RG = 3, VGE = 15V, L = 100H IC = IC110, VCE = 0.5 BVCES IC = IC110, VCE = 0.5 BVCES TJ = 150oC, ICE = IC110, VCE(PK) = 0.8 BVCES, VGE = 15V, RG = 3, L = 100H VGE = 15V VGE = 20V VCE(PK) = 480V VCE(PK) = 600V TC = 25oC TC = 150oC TC = 25oC TC = 150oC TC = 25oC MIN 600 15 3.0 200 60 TYP 25 1.5 1.7 5.2 MAX 250 2.0 1.8 2.0 6.0 100 UNITS V V A mA V V V nA A A
Collector To Emitter Breakdown Voltage Emitter To Collector Breakdown Voltage Collector To Emitter Leakage Current
CollectorTo Emitter Saturation Voltage
Gate To Emitter Threshold Voltage Gate To Emitter Leakage Current Switching SOA
Gate To Emitter Plateau Voltage On-State Gate Charge
VGEP QG(ON) td(ON)I trI td(OFF)I tfI EON EOFF RJC
-
8.1 162 216 40 45 320 230 1050 2500 -
180 250 400 275 0.6
V nC nC ns ns ns ns J J
oC/W
Current Turn-On Delay Time Current Rise Time Current Turn-Off Delay Time Current Fall Time Turn-On Energy Turn-Off Energy (Note 3) Thermal Resistance NOTE:
3. Turn-Off Energy Loss (EOFF) is defined as the integral of the instantaneous power loss starting at the trailing edge of the input pulse and ending at the point where the collector current equals zero (ICE = 0A). The HGTG30N60C3 was tested per JEDEC Standard No. 24-1 Method for Measurement of Power Device Turn-Off Switching Loss. This test method produces the true total turn-off energy loss. Turn-On losses include diode losses.
2
HGTG30N60C3 Typical Performance Curves
ICE, COLLECTOR TO EMITTER CURRENT (A) ICE, COLLECTOR TO EMITTER CURRENT (A) 150 125 100 TC = 150oC 75 TC = 25oC 50 25 0 4 6 8 10 12 VGE, GATE TO EMITTER VOLTAGE (V) TC = -40oC PULSE DURATION = 250s DUTY CYCLE <0.5%, VCE = 10V PULSE DURATION = 250s, DUTY CYCLE <0.5%, TC = 25oC 150 VGE = 15.0V 125 9.5V 100 75 50 25 0 9.0V 8.5V 8.0V 7.0V 0 2 4 6 8 VCE, COLLECTOR TO EMITTER VOLTAGE (V) 7.5V 10 12.0V 10.0V
FIGURE 1. TRANSFER CHARACTERISTICS
FIGURE 2. SATURATION CHARACTERISTICS
ICE, COLLECTOR TO EMITTER CURRENT (A)
150 125 100
ICE, COLLECTOR TO EMITTER CURRENT (A)
PULSE DURATION = 250s DUTY CYCLE <0.5%, VGE = 10V
TC = -40oC
150 PULSE DURATION = 250s DUTY CYCLE <0.5% 125 VGE = 15V TC = 150oC 100 TC = -40oC TC = 25oC
TC = 25oC 75 TC = 150oC 50 25 0 0 1 2 3 4 5 VCE, COLLECTOR TO EMITTER VOLTAGE (V)
75 50 25 0 0 1 2 3 4 5 VCE, COLLECTOR TO EMITTER VOLTAGE (V)
FIGURE 3. COLLECTOR TO EMITTER ON-STATE VOLTAGE
FIGURE 4. COLLECTOR TO EMITTER ON-STATE VOLTAGE
tSC , SHORT CIRCUIT WITHSTAND TIME (s)
70 ICE , DC COLLECTOR CURRENT (A) 60 50 40 30 20 10 0
VGE = 15V
VCE = 360V, RG = 25, TJ = 125oC
450 20 ISC 350 15 300 250 10 tSC 150 5 10 11 12 13 14 VGE , GATE TO EMITTER VOLTAGE (V) 100 15 200 400
25
50
75
100
125
150
TC , CASE TEMPERATURE (oC)
FIGURE 5. MAXIMUM DC COLLECTOR CURRENT vs CASE TEMPERATURE
FIGURE 6. SHORT CIRCUIT WITHSTAND TIME
3
ISC, PEAK SHORT CIRCUIT CURRENT (A)
25
500
HGTG30N60C3 Typical Performance Curves
200 td(ON)I , TURN-ON DELAY TIME (ns)
(Continued)
500 td(OFF)I , TURN-OFF DELAY TIME (ns) TJ = 150oC, RG = 3, L = 100H, VCE(PK) = 480V 400 VGE = 15V VGE = 10V 200
TJ = 150oC, RG = 3, L = 100H, VCE(PK) = 480V
100 VGE = 10V 50 40 30 20 VGE = 15V
300
10 10
100 20 30 40 50 60 10 ICE , COLLECTOR TO EMITTER CURRENT (A) 50 20 30 40 ICE , COLLECTOR TO EMITTER CURRENT (A) 60
FIGURE 7. TURN-ON DELAY TIME vs COLLECTOR TO EMITTER CURRENT
FIGURE 8. TURN-OFF DELAY TIME vs COLLECTOR TO EMITTER CURRENT
500 TJ = 150oC, RG = 3, L = 100H, VCE(PK) = 480V trI , TURN-ON RISE TIME (ns)
500 400 VGE = 10V tfI , FALL TIME (ns)
TJ = 150oC, RG = 3, L = 100H, VCE(PK) = 480V
300 VGE = 10V 200 VGE = 15V
100
VGE = 15V
10 10
100 20 30 40 50 60 10 20 30 40 50 60 ICE , COLLECTOR TO EMITTER CURRENT (A) ICE , COLLECTOR TO EMITTER CURRENT (A)
FIGURE 9. TURN-ON RISE TIME vs COLLECTOR TO EMITTER CURRENT
FIGURE 10. TURN-OFF FALL TIME vs COLLECTOR TO EMITTER CURRENT
8.0 EON , TURN-ON ENERGY LOSS (mJ) 7.0 6.0 5.0
EOFF, TURN-OFF ENERGY LOSS (mJ)
TJ = 150oC, RG = 3, L = 100H, VCE(PK) = 480V
6.0 TJ = 150oC, RG = 3, L = 100H, VCE(PK) = 480V 5.0
4.0 VGE = 10V or 15V 3.0
VGE = 10V 4.0 3.0 2.0 1.0 0 10 20 30 40 50 60 ICE , COLLECTOR TO EMITTER CURRENT (A) VGE = 15V
2.0 1.0 0 10
20
30
40
50
60
ICE , COLLECTOR TO EMITTER CURRENT (A)
FIGURE 11. TURN-ON ENERGY LOSS vs COLLECTOR TO EMITTER CURRENT
FIGURE 12. TURN-OFF ENERGY LOSS vs COLLECTOR TO EMITTER CURRENT
4
HGTG30N60C3 Typical Performance Curves
500 fMAX , OPERATING FREQUENCY (kHz)
(Continued)
ICE, COLLECTOR TO EMITTER CURRENT (A)
TJ = 150oC, TC = 75oC RG = 3, L = 100H
250
TJ = 150oC, VGE = 15V, L = 100H
100 VGE = 15V fMAX1 = 0.05/(tD(OFF)I + tD(ON)I) fMAX2 = (PD - PC)/(EON + EOFF) PD = ALLOWABLE DISSIPATION PC = CONDUCTION DISSIPATION (DUTY FACTOR = 50%) RJC = 0.6oC/W 1 5 10 20 30 40 60 ICE, COLLECTOR TO EMITTER CURRENT (A) VGE = 10V
200
150 LIMITED BY CIRCUIT
10
100
50
0 0 100 200 300 400 500 600 VCE, COLLECTOR TO EMITTER VOLTAGE (V)
FIGURE 13. OPERATING FREQUENCY vs COLLECTOR TO EMITTER CURRENT
VCE , COLLECTOR TO EMITTER VOLTAGE (V)
FIGURE 14. SWITCHING SAFE OPERATING AREA
8000 FREQUENCY = 400kHz 7000 C, CAPACITANCE (pF) 6000 5000 4000 3000 2000 COES 1000 CRES 0 0 5 10 15 20 25 VCE, COLLECTOR TO EMITTER VOLTAGE (V) CIES
IG(REF) = 3.54mA, RL = 20, TC = 25oC VGE, GATE TO EMITTER VOLTAGE (V) 600 15
480
12 VCE = 600V 9 VCE = 400V VCE = 200V
360
240
6
120
3
0 0 40 80 120 160 QG , GATE CHARGE (nC)
0 200
FIGURE 15. CAPACITANCE vs COLLECTOR TO EMITTER VOLTAGE
ZJC , NORMALIZED THERMAL RESPONSE
FIGURE 16. GATE CHARGE WAVEFORMS
100 0.5 0.2 t1 10-1 0.1 PD 0.05 0.02 0.01 10-2 10-5 SINGLE PULSE t2
DUTY FACTOR, D = t1 / t2 PEAK TJ = (PD X ZJC X RJC) + TC 10-3 10-2 10-1 100 101
10-4
t1 , RECTANGULAR PULSE DURATION (s)
FIGURE 17. IGBT NORMALIZED TRANSIENT THERMAL IMPEDANCE, JUNCTION TO CASE
5
HGTG30N60C3 Test Circuit and Waveforms
90% VGE L = 100H RHRP3060 VCE + 90% VDD = 480V ICE 10% td(OFF)I tfI trI td(ON)I EOFF 10% EON
RG = 3
-
FIGURE 18. INDUCTIVE SWITCHING TEST CIRCUIT
FIGURE 19. SWITCHING TEST WAVEFORMS
Handling Precautions for IGBTs
Insulated Gate Bipolar Transistors are susceptible to gate-insulation damage by the electrostatic discharge of energy through the devices. When handling these devices, care should be exercised to assure that the static charge built in the handler's body capacitance is not discharged through the device. With proper handling and application procedures, however, IGBTs are currently being extensively used in production by numerous equipment manufacturers in military, industrial and consumer applications, with virtually no damage problems due to electrostatic discharge. IGBTs can be handled safely if the following basic precautions are taken: 1. Prior to assembly into a circuit, all leads should be kept shorted together either by the use of metal shorting springs or by the insertion into conductive material such as "ECCOSORBD LD26" or equivalent. 2. When devices are removed by hand from their carriers, the hand being used should be grounded by any suitable means - for example, with a metallic wristband. 3. Tips of soldering irons should be grounded. 4. Devices should never be inserted into or removed from circuits with power on. 5. Gate Voltage Rating - Never exceed the gate-voltage rating of VGEM. Exceeding the rated VGE can result in permanent damage to the oxide layer in the gate region. 6. Gate Termination - The gates of these devices are essentially capacitors. Circuits that leave the gate opencircuited or floating should be avoided. These conditions can result in turn-on of the device due to voltage buildup on the input capacitor due to leakage currents or pickup. 7. Gate Protection - These devices do not have an internal monolithic Zener Diode from gate to emitter. If gate protection is required an external Zener is recommended.
Operating Frequency Information
Operating frequency information for a typical device (Figure 13) is presented as a guide for estimating device performance for a specific application. Other typical frequency vs collector current (ICE) plots are possible using the information shown for a typical unit in Figures 4, 7, 8, 11 and 12. The operating frequency plot (Figure 13) of a typical device shows fMAX1 or fMAX2, whichever is smaller at each point. The information is based on measurements of a typical device and is bounded by the maximum rated junction temperature. fMAX1 is defined by fMAX1 = 0.05/(td(OFF)I + td(ON)I). Deadtime (the denominator) has been arbitrarily held to 10% of the on-state time for a 50% duty factor. Other definitions are possible. td(OFF)I and td(ON)I are defined in Figure 19. Device turnoff delay can establish an additional frequency limiting condition for an application other than TJM. td(OFF)I is important when controlling output ripple under a lightly loaded condition. fMAX2 is defined by fMAX2 = (PD - PC)/(EOFF + EON). The allowable dissipation (PD) is defined by PD = (TJM - TC)/RJC.The sum of device switching and conduction losses must not exceed PD. A 50% duty factor was used (Figure 13) and the conduction losses (PC) are approximated by PC = (VCE x ICE)/2. EON and EOFF are defined in the switching waveforms shown in Figure 19. EON is the integral of the instantaneous power loss (ICE x VCE) during turn-on and EOFF is the integral of the instantaneous power loss (ICE x VCE) during turn-off. All tail losses are included in the calculation for EOFF; i.e. the collector current equals zero (ICE = 0).
All Intersil semiconductor products are manufactured, assembled and tested under ISO9000 quality systems certification.
Intersil semiconductor products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see web site www.intersil.com 6
ECCOSORBD is a Trademark of Emerson and Cumming, Inc.


▲Up To Search▲   

 
Price & Availability of HGTG30N60C3

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X